EPEVER IPT1500-42
Description
The IPT series, a high-frequency sine wave inverter, adopts a fully digital intelligent design and voltage-current dual closed-loop control algorithm. Featured with fast response, high conversion efficiency, low Total Harmonic Distortion (THD), and high reliability running, the IPT series can be widely used in the DC-AC off-grid systems (such as vehicle systems, security monitoring systems, emergency lighting systems, household power systems, field power systems, and other systems requiring higher power quality).
Features:
- Pure sine wave output
- Input to output electrical isolation
- Output power factor up to 1
- Input Protection: Low-voltage, Over-voltage
- Output Protection: Overload, Short circuit, Overheating
- RS485 com. port to realize remote monitoring
- External switch design, matched with EPEVER products, to expand inverter control function and reduce power consumption
- Diversified AC output sockets
- EN/IEC62109-1/2, EN61000-6-2/4, and FCC approved
TECHNICAL SPECIFICATIONS:
Parameter
Continuous output power : 1500W@35℃@Rated input voltage
Surge power : 3000W@5S
Surge current when power on① : < 50A
Output voltage : 220VAC (±3%); 230VAC (-6%~+3%); 240VAC (-9%~+3%)
Output frequency : 50/60Hz ± 0.2%
Output wave : Pure Sine Wave
Output distortion THD : THD ≤ 3% (Resistive load)
Load power factor : 0.2 ~ 1 (Load power ≤ Continuous output power)
Rated input voltage : 48VDC
Input voltage range : 43.2 ~ 64.0VDC
Rated output efficiency② : > 92.5%
Max. output efficiency③ : > 94% (30% loads)
Idle current : < 0.1A
No-load current : < 0.5A
RS485 com. port : 5VDC/200mA
Mechanical parameters
Input terminal : M6
Dimension (L x W x H) : 387 × 228 × 118mm
Mounting size (L x W) : 361 × 145mm
Mounting hole size : Φ6mm
Net Weight : 5.2kg
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For other products, the actual surge current prevails.
② It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
③ It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.